CHFRZ - EMERY 3006 SYNTHETIC HYDROCARBON 6 CST FLUID

  • MSDS: CHFRZ
  • Manufacturer: QUANTUM CHEMICAL CORP
  • Product Name: EMERY 3006 SYNTHETIC HYDROCARBON 6 CST FLUID
  • National Stock Number: 6850-00N086712
Product Identification

Product ID:EMERY 3006 SYNTHETIC HYDROCARBON 6 CST FLUID
MSDS Date:11/02/1988
FSC:6850
NIIN:00N086712
MSDS Number: CHFRZ

Responsible Party
QUANTUM CHEMICAL CORPORATION
4900 ESTE AVE
CINCINNATI, OH 45232
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 513-482-2297

Preparer: ROBERT E. BORGERDING

Cage: 78918

Contractor
QUANTUM CHEMICAL CORPORATION USI DIVISION
429550 CINCINNATI, OH 45249 US

Telephone: 713-479-2873/800-424-9300(CHEMTREC)

Cage: 78918

Ingredients

1-DECENE, HOMOPOLYMER, HYDROGENATED; (POLYALFHAOLEFIN)

CAS: 68037-01-4

Fraction By Weight: 100%

OSHA PEL N/K

ACGIH TLV: N/K


PREFERABLY BY MOUTH-TO-MOUTH. GET MEDICAL

RTECS: 9999999ZZ


TO SECURE CNTNRS. WHERE NEC, COLLECT USING

RTECS: 9999999ZZ


USER SHOULD DETERMINE IF RELEASE IF REPORTABLE UNDER

RTECS: 9999999ZZ


OF ANTICIPATED EXPOSURE IF THERE IS

RTECS: 9999999ZZ


CONJ CHANGES. MATL IS NOT CLASSIFIED AS AN

RTECS: 9999999ZZ


MATL IS NOT CLASSIFIED AS PRIMARY

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50:(ORAL,RAT) >5 G/KG.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:ESTIMATED LC50 FOR 1 HR EXPOS TO
2 CST PAO WAS 4.65 MG/L(RATS), WHICH IS CONSIDERED TOX. IN ORDER TO
DETERM LC50 VALUE, EXTREMELY HEAVY MIST OF PAO WERE REQD. THE HEAVY
MIST AT NEC CONC MADE VIS IBILITY DFCLT & WOULD BE DFCLT TO WORK IN
FOR ANY PERIOD OF TIME. AUTHOR RPTD THAT HISTOPATHOLOGICAL (EFTS OF
OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CHANGES MAY HAVE BEEN RESPONSE TO
PHYSICAL INSULT RATHER THAN SPECIFIC CMPD RELATED TOX EFT & THAT
CST POA MAY BE CONSIDERED NON-HAZ FOR ALL PRACTICAL PURPOSES BY
INHAL. INGEST:MATL IS NOT CL ASSIFIED AS TOX BY ORAL ADMIN AS
DEFINED IN 16 CFR 1500. EYE CONT:EYES OF 5 RABBITS WERE FOUND TO
SHOW EVID OF (ING 6)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST:DO NOT INDUCE VOMIT. IF VICTIM IS CONSCIOUS & ABLE TO
SWALLOW, PROMPTLY HAVE VICTIM DRINK WATER TO DILUTE. DO NOT GIVE
SODIUM BICARBONATE, FRUIT JUICES/VINEGAR. NEVER GIVE ANYTHING BY
MOUTH IF VICTIM IS UNCON/HAVING CONVLS. CALL MD/POIS CTL CTR
IMMED. SKIN:WASH AFFECTED AREA. EYES:IMMED FLUSH W/PLENTY OF COOL
WATER FOR AT LST 15 MINS. DO NOT LET VICTIM RUB EYES. INHAL:IMMED
REMOVE (SUPDAT)

Fire Fighting

Flash Point Method:COC
Flash Point:464F,240C
Extinguishing Media:USE WATER SPRAY, DRY CHEMICAL, FOAM OR CARBON
DIOXIDE.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROT EQUIP .
(INDIVIDUALS SHOULD PERFORM ONLY THOSE FIRE FIGHTING PROCS FOR
WHICH THEY HAVE BEEN TRAINED). WATER MAY (SUPDAT)
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:AVOID UNCONTROLLED RELS OF THIS MATL. WHERE
SPILLS ARE POSS, COMPREHENSIVE SPILL RESPONSE PLAN SHOULD BE DEVEL
& IMPLEMENTED. WEAR APPROP NIOSH APPRVD RESP PROT & PROT CLTHG AS
DESCRIBED IN EMPLOYEE P ROT SECTION. CNTN SPILLED MATL. TRANSFER
(ING 3)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NO SPECIAL PRECAUTIONS NECESSARY.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:WHERE EXPOSURE IS LIKELY TO EXCEED ACCEPTABLE
CRITERIA, USE NIOSH APPROVED RESPIRATORY EQUIPMENT. RESPIRATORS
SHOULD BE SELECTED BASED ON FORM & CONCENTRATION OF CONTAMINANT IN
AIR & I/A/W OSHA (29 CF R 1910.134).
Ventilation:HANDLE IN PRESENCE OF ADEQUATE VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPRVD EYE WASH FOUNTAIN & DELUGE
SHOWER . WEAR PROT CLTHG WHICH IS IMPERVIOUS TO PROD FOR DURATION
(ING 5)
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC:BE INEFT BUT SHOULD BE USED TO KEEP FIRE-EXPOS CNTNRS
COOL. IF SPILL/LEAK HAS NOT IGNITED, USE WATER SPRAY TO DISPERSE
VAPS. WATER SPRAY MAY BE USED TO FLUSH SPILLS AWAY FROM FIRE. WAS
TE DISP METH:RECLAIM WHERE POSS. FIRST AID PROC:VICTIM TO FRESH
AIR. IF VICTIM HAS STOPPED BRTHG GIVE ARTF RESP, (ING 2)

Chemical Properties

Boiling Pt:B.P. Text:781F,416C
Vapor Pres:<1 @ 20C
Spec Gravity:0.828
Solubility in Water:INSOLUBLE
Appearance and Odor:COLORLESS FLUID; ODORLESS.

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:AVOID HEATING TO DECOMPOSITION. USER IS
ADVISED TO HAVE SAFETY EXPERT EVALUATE SPECIFIC CONDITIONS OF USE.
Hazardous Decomposition Products:DECOMPOSITION MAY PRODUCE CARBON
MONOXIDE & CARBON DIOXIDE.

Disposal

Waste Disposal Methods:DISP MUST BE I/A/W FED, STATE & LOC REGS . ALL
RECOVERED MATL SHOULD BE PACKAGED, LABELED, TRANSPORTED & DISPOSED
OR RECLAIMED IN CONFORMANCE W/APPLIC LAWS & REGS & IN CONFORMANCE
W/GOOD ENGINEE RING PRACTICES. AVOID LANDFILLING OF LIQS.(SUPDAT)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.